Panasonic CS-XC12CKQ + CS-XC9CKQ Service Manual & Repair Guide
|
File Data:
| Contact Seller: | repairpro, Member since 06/04/2008 |
| URL: |
|
| Embed: |
|
Is your Panasonic Air Conditioner letting you down?
Why replace when you can upgrade or repair?
This Service & Repair manual is used by the
official Technicians
You will learn about:
- Specifications & Features
- Block/Wiring/Electronic Diagrams
- Printed Circuit Board
- Installation & Operation Instructions
- Troubleshooting
- Servicing Mode
- Disassembly and Assembly Instructions
- Technical Data
- Exploded View and Replacement Parts List
This Service Manual covers the following models:
Panasonic CS-XC9CKQ
Panasonic CU-XC9CKQ
Panasonic CS-XC12CKQ
Panasonic CU-XC12CKQ
This manual is very detailed and used by the
official Panasonic technicians. It will help you
troubleshoot and repair your Air Conditioner!
Fully illustrated with Pictures and Step-by-Step
Instructions!
All pages are printable, so run off what you need
& take it with you into the home, office or
repairshop.
Do your own repairs and Save Money!
SPECIFICATIONS:
Language: English
Format: PDF
Platform: Windows & MAC
**INSTANT DOWNLOAD**
Right after payment, you will have instant access
to you download!
No shipping fee, no waiting on postal delivery.
You can start doing your repairs right away!
*************************************************************
Looking for a manual but can't find it anywhere?
Please contact us with your request! We have got
one of the largest manual-databases out there, so
a good change we can help you out!
*************************************************************
Why replace when you can upgrade or repair?
This Service & Repair manual is used by the
official Technicians
You will learn about:
- Specifications & Features
- Block/Wiring/Electronic Diagrams
- Printed Circuit Board
- Installation & Operation Instructions
- Troubleshooting
- Servicing Mode
- Disassembly and Assembly Instructions
- Technical Data
- Exploded View and Replacement Parts List
This Service Manual covers the following models:
Panasonic CS-XC9CKQ
Panasonic CU-XC9CKQ
Panasonic CS-XC12CKQ
Panasonic CU-XC12CKQ
This manual is very detailed and used by the
official Panasonic technicians. It will help you
troubleshoot and repair your Air Conditioner!
Fully illustrated with Pictures and Step-by-Step
Instructions!
All pages are printable, so run off what you need
& take it with you into the home, office or
repairshop.
Do your own repairs and Save Money!
SPECIFICATIONS:
Language: English
Format: PDF
Platform: Windows & MAC
**INSTANT DOWNLOAD**
Right after payment, you will have instant access
to you download!
No shipping fee, no waiting on postal delivery.
You can start doing your repairs right away!
*************************************************************
Looking for a manual but can't find it anywhere?
Please contact us with your request! We have got
one of the largest manual-databases out there, so
a good change we can help you out!
*************************************************************
User tags:
Votes: Rate it! (No votes yet - 0!)
Reviews: Review it! (This product has no reviews yet)
|
Automated PDF to Text preview page 4 to 6:
CS-XC9CKQ CU-XC9CKQ / CS-XC12CKQ CU-XC12CKQ Indoor Unit AUTO OFF / ON Automatic Operation Button Press for < 5s to operate Automatic operation mode. (Used when the remote control cannot be used.) Press continuously for 5s or < 10s to operate Test Run/Pump down. "Beep" sound will be heard at the 5th second. (Used when test running or servicing.) Press continuously for 10s or < 15s to omit or resume the remote control signal receiving sound. "Beep, beep" sound will be heard at the 10th second. Press continuously for 15s and above to testify oxygen operation. "Beep, beep, beep" sound will be heard at the 15th second. Random Auto Restart Control Operation is restarted randomly after power failure at previous setting mode. Anti-Freezing Control Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry) Ionizer Control Ionizer control for generate negative ion in discharge air. Indoor Fan Speed Control High, Medium and Low. Automatic Fan Speed Mode _ Cooling : Fan rotates at Hi, Me and SLo speed. Deodorizing control is available. _ Soft Dry : Fan rotates at Lo- speed. Deodorizing control is available. Operation Indication Lamps (LED) POWER (Green)......... Lights up in operation, blinks in Automatic Operation Mode judging. (Green) .... ... Lights up in Oxygen Mode Operation. ION (Green) ............ Lights up in Ionizer Mode Operation. QUIET (Orange)......... Lights up in Quiet Mode Operation. TIMER (Orange)......... Lights up in Timer Setting. Airflow Direction Control Automatic air swing and manual adjusted by remote control for vertical airflow. Manually adjusted by hand for horizontal airflow. Operation Mode Cooling, Soft Dry, Air Circulation and Automatic Mode. Starting Current Control Indoor fan motor is delayed for 1.6 seconds when indoor, outdoor fan motor and compressor starts simultaneously. Oxygen Operation To supply oxygen enrich air. Time Delay Safety Control Restarting is inhibited for appro. 3 minutes. Quiet Operation To provide quiet operation. 7 Minutes Time Save Control Cooling Operation only. 4 CS-XC9CKQ CU-XC9CKQ / CS-XC12CKQ CU-XC12CKQ Outdoor Unit Compressor Reverse Rotation Protection Control · To protect compressor from reverse rotation when there is a instantaneous power failure. Overload Protector · 2-Stage OLP to protect the compressor. Overload Protector will trip when Temperature of compressor increases to 120°C. High temperature or high current flows to compressor. (Refer circuit diagram for OLP characteristic) 60 Secs. Forced Operation Control · Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Outdoor Fan Operation Control · Temperature Fuse. 5 CS-XC9CKQ CU-XC9CKQ / CS-XC12CKQ CU-XC12CKQ 3 Product Specifications Power Source Cooling Capacity Moisture Removal Airflow Method Unit Phase, Voltage, Cycle kW (BTU/h) l/h (Pint/h) OUTLET CS-XC9CKQ Single, 230, 60 Hz 2.76 (9,420) 1.6 (3.4) SIDE VIEW TOP VIEW CU-XC9CKQ INTAKE Air Volume Indoor Indoor Indoor Indoor Air Air Air Air (Lo) (Me) (Hi) (SHi) Noise Level Electrical Data Input Power Running Current EER Starting Current Piping Connection Port (Flare piping) Pipe Size (Flare piping) Drain Inner diameter Hose Length Power Cord Length Number of core-wire Dimensions Height Width Depth Net Weight Compressor Type Motor Rated Air Circulation Motor Rated Fan Speed Type Output Type Material Type Input Output Low Medium High SuperHigh m3/min (cfm) m3/min (cfm) m3/min (cfm) m3/min (cfm) dB (A) Power level dB W A W/W (BTU/hW) A inch inch inch inch mm mm m inch (mm) inch (mm) inch (mm) lb (kg) 6.8 (240) 8.0 (280) 9.9 (350) 10.9 (380) High 36, Low 26 High 49 790 3.7 3.49 (11.8) 23.0 -- -- 32.6 (1,150) -- High 49 High 64 W W W rpm rpm rpm rpm Heat Exchanger Description Tube material Fin material Fin Type Row / Stage FPI Size (W × H × L) Refrigerant Control Device Refrigeration Oil Refrigerant (R-22) Thermostat Protection Device mm (cm3) g (oz) G ; 3-way valve 3/8" L ; 2-way valve 1/4" G ; (gas side) 3/8" L ; (liquid side) 1/4" -- -- -- -- 21 - 1/4 (540) 30 - 23/32 (780) 11 - 3/8 (289) 68 (31.0) Rotary (1 cylinder) rolling piston type -- Induction (2-poles) -- 600 Cross-flow Fan Propeller Fan AS + Glass Fiber 20% PP Resin Induction (4-poles) Induction (6-poles) 42.0 72.4 15 30 780 -- 920 -- 1,140 835 1,250 -- Evaporator Condenser Copper Copper Aluminium (Pre Coat) Aluminium (Blue Coat) Slit Fin Louver Fin (Plate fin configuration, forced draft) 2 × 15 1 × 20 19 17 610 × 315 × 25.4 841 × 508 × 22 -- Capillary Tube -- SUNISO 4GDID or ATMOS M60 (290) -- 890 (31.4) Electronic Control -- -- 2 Stage Overload Protector G ; Half Union 3/8" L ; Half Union 1/4" G ; (gas side) 3/8" L ; (liquid side) 1/4" 12 650 1.9 3 (1.5 mm 2) 10 - 13/16 (275) 31 - 15/32 (799) 9 -9/32 (236) 22 (10.0) -- 6 |


